The Champion-SCR2
In keeping with the reliability and performance of our classic CHAMPION-ATC Electronic Tankless Water Heater, we have developed the newer and more advanced CHAMPION-SCR2. The new CHAMPION-SCR2 incorporates new space age technology and features a faster and more accurate temperature sampling system, a manual resettable thermostat and a new air/water deferential analyzing system to prevent dry starts, (which is a key problem for other tankless systems.)

On-Demand Hot Water Saves Money
By heating water only as it is needed the CHAMPION-SCR2 Tankless Water Heater eliminates the need for bulky water heaters that heat water continuously. This can reduce hot water costs up to 60% over conventional electric water heaters. The CHAMPION-SCR2's high efficiency is in part due to its dedicated analog microprocessor that samples input and output temperatures 21 times per second.

This power control system analyzes the data and manages power usage for maximum efficiency and temperature stability. At rest, the CHAMPION-SCR2 uses no power at all.


Available in seven models, the CHAMPION-SCR2 is ideal for a wide range of application. One CHAMPION-SCR2 unit can supply the hot water needs of home and apartments, and in some applications, energy saving can pay back unit cost in less than one year.

Due to its shielded incoloy heating elements and copper & brass casing, the CHAMPION-SCR2 is ideal in any application where mineral deposits shorten the life of a conventional water heater.

The CHAMPION-SCR2 Tankless Water Heater comes with a 10 year warranty on all water-carrying components and all other parts are warrantied for one year. Installation is quick and easy, requiring no venting or pressure relief valves, and the CHAMPION-SCR2 compact size allows installation almost anywhere. The CHAMPION-SCR2 is without a doubt the Tankless Water Heater for the 21st century.


Specifications:
Compliance UL-#499
Standards ANSI-Z, 10.03
Tested Applied Research Lab # 29-580
Dade Approval # 97-0627.16
Dimensions 7" W x 10" H x 2-3/4 D
Weight 8 Pounds
Materials Brass Casing
Pipe Fitting 1/2" Standard Pipe
Pressure 5 PSI-Min./150 PSI-Max
Voltage 220 VAC Std.(208/277 Avail.)
Elements Dual Incoloy/Nichrome
Energy Efficiency Up to 99.5%
Activation 0.4 GPM-on/).3 GPM-off
Indicators Red-on/Amber-stand by
Warranty 10 years on casing 1 year on components
Protection Dual Microtemp Thermofuse - Manual Resetable Thermostat

U.S. Patent # 5,408,578


Note that the KW and Amps are controlled by the setting on the Power Mode.

Check specifications on unit used. Voltage, amperage, breaker and wire may vary depending on local electrical standards. Consult a professional plumber or electrician for guidance.

The electrical specifications are based on 220 volts. It should be noted that higher voltage will increase power, just as lower voltage will have the reverse effect. The (POWER MODE CONTROL) can be adjusted to compensate allowing the user to increase or decrease water temperature. For best performance adjust temperature at MEDIUM FLOW (approximately 1 GPM) this is the average water flow at any faucet with an aerator.

Remember, that any adjustments made on your unit will take seconds to reach point of use. DO NOT OVER HEAT WATER. Water temperature from 105F to 120F is adequate for all practical purposes.


MODELS
Model Max KW at 220V Volts Max Amps at 220V
C-120 11.8KW 220V 54
C-85 8.5KW 220V 38


Uses
House Apartments Condominiums Beauty Salons
Hospitals Boats Laboratories Campers
Offices Schools Cottages Restaurants
Barber Shops Warehouses    

Anywhere hot water is needed


We reserve the right to amend specifications as new technology develops.



TANKLESS STATISTICS

FPL stated if TANKLESS were used with a $70.00 month bill you would save $13.00 per month.

That is an 18.5 percent savings per month!!

$13.00 times 7 million people which FPL has on line would save the consumer $91 million dollars a month.

12 months times 91 million dollars a month totals $1,092,000,000 annual savings for the consumers per year.

If you look at my utility bill for last month ($151.80) and divide the total amount into kWh used (1669) it comes out to approximately 9.09 cents per kWh.

If you take 9.09 cents which is approximately 11KWH per dollar into $1,092,000,000 it amounts to approximately 99,272,727 kWh which is how much electricity this state would save at a minimum per year!!!!

FPL should encourage the consumer converting to tankless hot water heaters. FPL should institute a rebate program like they have now with high energy efficient rated air conditioners to conserve energy!!!

Isn't it time that we pass into legislation a law stating that any new construction whether residential or commercial is required to use tankless hot water heaters to conserve energy which this state needs desperately???